<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>general</ParameterFamily>
<LongName>
fault_reset_count
</LongName>
<Name>
fcnt
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>All</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Number of times the recorder has started up after a reset due to a software
crash.  This includes resets initiated by "confused" firmware, like when plates
are in "impossible" situations due to a mix of workstation images and diagnostic
monitor plate commnads.  This count also includes resets from the boot monitor
made after loading new firmware.
</text></DescriptionText>
<DescriptionText><text>
This statistics parameter is usually viewed with the "list stats" command.  It
is reset by the "nvs init stats" command.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 0</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
state
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/list_stats.xml</LinkAddress><LinkTitle>Command: list stats</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:50 2008 PST
</Updated>
<Links>
</Links>